Owing to the huge appreciation from our clients, we have enabled ourselves to manufacture, supply and export Microprocessor Solution Analyzer Kit. The raw materials are procured from reliable sources of the industry to manufacture these products. The analyzer kit comprises latest water checking and soil checking instruments. Microprocessor Solution Analyzer Kit is stored in a compact briefcase which is easy to handle and ensures safety of the instruments.
Features:
Technical Specifications
pH Range: 0-14 pHResolution: 0.01pH Accuracy : + 0.01 pH ( relative) Temp. Comp. : Automatic with Pt100 Sensor &Manual by keys Buffer Recognition : 4.00 , 7.00 , 9.20 ( Automatic) Calibration Automatic & Manual 2 Point, 3 Point(Prog.)
|
Dissolved Oxygen Range : 0 to 20 ppmResolution : 0. 1 ppm Calibration : Automatic Accuracy : + 0.2 ppm + 1digit Temp. Comp.: Automatic with Pt100 Sensor & Manual By keys Pressure comp : 0-999 mm of Hg ( Manual) Salinity Correction : 0-20 mg/l |
mv/ORP Range: 1999 to +1999 mVResolution: 1 mV Calibration: Manual Accuracy : + 0.1% + 1digit |
Temperature Range: 200 to +200 degree CResolution : 0.1 degree C Accuracy : + 0.2% + 1digit Input : Pt100 Calibration : Manual |
Conductivity Range : 0-1000 mS/cmRange Selection : Automatic Resolution : 0.01 uS/cm Accuracy: + 0.5% Temp. Comp. : Automatic with Pt100 Sensor Ref. Temp. : 25 degree C/20 degree C(Prog.) Temp. Co-efficient : 0-4% adjustable Cell constant : 0.05 to 2.0 adjustable |
TDS Range : 0-1000 pptRange Selection : Automatic Resolution : 0.1 ppm Accuracy : + 0.5% TDS factor: 0.5 by default( adjustable) |
Salinity Range : 0-50 pptResolution: 0.1 ppt Temp. Comp : Automatic Accuracy : + 0.5% Salinity factor : 0.75 by default( adjustable) |
General Display : 16 characters X 2 lines alpha Numeric BL LCDDisplay format : Temp. and parameter Simultaneously Real Time Display: 24 Hour Mode With Date & Time Controls : By soft keys Menu Driven Storage: up to 1000 samples Power supply: 230 V +10 % 50 Hz OR 12 V battery Digital Output : Serial RS-232 Parallel Centronics Print format : All Data Date Wise (Programmable) Error Indication : pH Error,ORP Error,T-Error |
Option RS232 & Parallel output available for interfacing to computer/printer |
|
Accessories pH electrodeBuffer solutions Conductivity/TDS/Salinity Cell Temp. probe DO probe, DO membranes, KCL Operation manual ORP Electrode AT EXTRA COST |
Appearance and specifications subject to change due to continuous development
DATE |
TIME |
TEMP(DegC) |
PARAMETER |
MODE |
SP.No |
12/12/09 |
11:18 |
T= 020.0 |
pH= 07.00 |
MANUL |
001 |
12/12/09 |
11:18 |
T= 020.0 |
mV= 0000 |
MANUL |
002 |
12/12/09 |
11:18 |
T= 020.0 |
DO=00.0 ppm |
MANUL |
003 |
12/12/09 |
11:19 |
T= 020.0 |
C=00.00us/cm |
MANUL |
004 |
12/12/09 |
11:19 |
T= 020.0 |
TDS=00.00ppm |
MANUL |
005 |
12/12/09 |
11:19 |
T= 020.0 |
SAL=000.5ppt |
MANUL |
006 |
Price: